{"id":3239,"date":"2026-04-27T05:18:02","date_gmt":"2026-04-27T05:18:02","guid":{"rendered":"https:\/\/niunielec.com\/?post_type=product&#038;p=3239"},"modified":"2026-04-27T05:18:02","modified_gmt":"2026-04-27T05:18:02","slug":"nu-gfpt-12-630-environmentally-friendly-pt-switch","status":"publish","type":"product","link":"https:\/\/niunielec.com\/fr\/product\/nu-gfpt-12-630-environmentally-friendly-pt-switch\/","title":{"rendered":"NU-GFPT-12-630 Interrupteur PT semi-ferm\u00e9 pour GIS respectueux de l'environnement"},"content":{"rendered":"<h2 id=\"h2-1\"><span style=\"font-size: 75%;\"><strong>Commutateur PT NU-GFPT-12-630 haute performance pour installations GIS 12 kV respectueuses de l'environnement<\/strong><\/span><\/h2>\n<h3><strong><span style=\"font-size: 75%;\">Description du produit<\/span><\/strong><\/h3>\n<p>Le commutateur NU-GFPT-12-630 PT est une solution sp\u00e9cialis\u00e9e con\u00e7ue pour les armoires de transformateurs de tension (PT) isol\u00e9es au gaz et respectueuses de l'environnement, de 12 kV\/630 A. Il remplit des fonctions essentielles en g\u00e9rant les courants nominal et de charge du circuit principal, tout en offrant des capacit\u00e9s indispensables d'isolation et de fermeture. Ce commutateur est indispensable pour fournir l'alimentation de commande, permettre une mesure pr\u00e9cise de la tension et prendre en charge les circuits de tension pour l'instrumentation, le tout dans une conception compacte et fiable conforme aux normes GB3804-2017 et GB3906-2020.<\/p>\n<h3><span style=\"font-size: 75%;\"><strong>Applications<\/strong><\/span><\/h3>\n<p>Utilisation principale dans les armoires de transformation \u00e0 gaz (PT) de 12 kV respectueuses de l'environnement destin\u00e9es aux r\u00e9seaux \u00e9lectriques urbains.<\/p>\n<p>Fournit l'alimentation de mesure et de commande pour les instruments de mesure et les relais de protection.<\/p>\n<p>Convient aux sous-stations n\u00e9cessitant une isolation hautement fiable dans un encombrement r\u00e9duit.<\/p>\n<h3><strong><span style=\"font-size: 75%;\">Param\u00e8tres techniques<\/span><\/strong><\/h3>\n<table width=\"1131\">\n<tbody>\n<tr>\n<td width=\"51\">&nbsp;<\/p>\n<p>Non.<\/td>\n<td width=\"565\">Objet<\/td>\n<td width=\"75\">Unit\u00e9<\/td>\n<td width=\"135\">Param\u00e8tres<\/td>\n<td width=\"305\">Remarque<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">1<\/td>\n<td width=\"565\">Tension nominale<\/td>\n<td width=\"75\">kV<\/td>\n<td width=\"135\">12<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">2<\/td>\n<td width=\"565\">Courant nominal<\/td>\n<td width=\"75\">A<\/td>\n<td width=\"135\">630<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">3<\/td>\n<td width=\"565\">Courant de tenue nominal de courte dur\u00e9e<\/td>\n<td width=\"75\">kA\/S<\/td>\n<td width=\"135\">20\/4\u00a0 25\/4<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">4<\/td>\n<td width=\"565\">Courant de r\u00e9sistance nominal de cr\u00eate<\/td>\n<td width=\"75\">kA<\/td>\n<td width=\"135\">50\/63<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">5<\/td>\n<td width=\"565\">Courant nominal de fermeture en cas de court-circuit<\/td>\n<td width=\"75\">kA<\/td>\n<td width=\"135\">50\/63<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">6<\/td>\n<td width=\"565\">Temps de fermeture en cas de court-circuit<\/td>\n<td width=\"75\">temps<\/td>\n<td width=\"135\">30<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">7<\/td>\n<td width=\"565\">Tension de tenue \u00e0 la fr\u00e9quence du r\u00e9seau : terre\/phase \u00e0 phase<\/td>\n<td width=\"75\">kV<\/td>\n<td width=\"135\">42<\/td>\n<td width=\"305\">Dans l'air sec ou dans l'azote Dans l'air sec ou dans l'azote<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">8<\/td>\n<td width=\"565\">Tension de tenue \u00e0 la fr\u00e9quence du r\u00e9seau : rupture<\/td>\n<td width=\"75\">kV<\/td>\n<td width=\"135\">48<\/td>\n<td width=\"305\">Dans l'air sec ou dans l'azote Dans l'air sec ou dans l'azote<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">9<\/td>\n<td width=\"565\">Impulsion de foudre : terre\/phase \u00e0 phase<\/td>\n<td width=\"75\">kV<\/td>\n<td width=\"135\">75<\/td>\n<td width=\"305\">Dans l'air sec ou dans l'azote Dans l'air sec ou dans l'azote<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">10<\/td>\n<td width=\"565\">Impulsion de foudre : rupture<\/td>\n<td width=\"75\">kV<\/td>\n<td width=\"135\">85<\/td>\n<td width=\"305\">Dans l'air sec ou dans l'azote Dans l'air sec ou dans l'azote<\/td>\n<\/tr>\n<tr>\n<td width=\"51\">11<\/td>\n<td width=\"565\">R\u00e9sistance de la boucle principale<\/td>\n<td width=\"75\">u\u03a9<\/td>\n<td width=\"135\">\u2264 30<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<tr>\n<td width=\"51\">12<\/td>\n<td width=\"565\">Dur\u00e9e de vie m\u00e9canique<\/td>\n<td width=\"75\">temps<\/td>\n<td width=\"135\">5000<\/td>\n<td width=\"305\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong><span style=\"font-size: 75%;\">Dessin<\/span><\/strong><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-3242\" src=\"https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint-694x768.webp\" alt=\"Commutateur de puissance semi-ferm\u00e9 nu gfpt 12 630 pour appareillage de commutation \u00e0 gaz (GIS) respectueux de l&#039;environnement\" width=\"694\" height=\"768\" srcset=\"https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint-694x768.webp 694w, https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint-397x440.webp 397w, https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint-768x850.webp 768w, https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint-600x664.webp 600w, https:\/\/niunielec.com\/wp-content\/uploads\/2026\/04\/nu-gfpt-12-630-pt-switch-dimensional-blueprint.webp 838w\" sizes=\"auto, (max-width: 694px) 100vw, 694px\" \/><\/p>\n<h3><strong><span style=\"font-size: 75%;\">FAQ sur les commutateurs PT respectueux de l'environnement<\/span><\/strong><\/h3>\n<ul>\n<li>Q : Ce commutateur PT est-il adapt\u00e9 aux climats extr\u00eamement froids ?<\/li>\n<\/ul>\n<p>R : Oui. Il a \u00e9t\u00e9 v\u00e9rifi\u00e9 que le NU-GFPT-12-630 fonctionne de mani\u00e8re fiable \u00e0 des temp\u00e9ratures ambiantes pouvant descendre jusqu'\u00e0 -40 \u00b0C, ce qui en fait un choix id\u00e9al pour les installations sur le r\u00e9seau \u00e9lectrique dans les r\u00e9gions nordiques.<\/p>\n<ul>\n<li>Q : Ce commutateur de transformateur de potentiel est-il conforme aux normes de s\u00e9curit\u00e9 internationales ?<\/li>\n<\/ul>\n<p>R : Il est enti\u00e8rement conforme aux exigences techniques des normes GB3804-2017 et GB3906-2020, garantissant ainsi une s\u00e9curit\u00e9 et des performances m\u00e9caniques conformes aux normes.<\/p>\n<ul>\n<li>Q : Peut-on l'installer en haute altitude ?<\/li>\n<\/ul>\n<p>R : La version standard est con\u00e7ue pour des altitudes allant jusqu'\u00e0 2 000 m. Pour des exigences sup\u00e9rieures, veuillez contacter notre \u00e9quipe technique afin d'obtenir une solution sur mesure.<\/p>\n<p><span style=\"font-size: 105%;\"><strong><a href=\"https:\/\/niunielec.com\/fr\/contact-us\/\">Contactez-nous<\/a> Contactez-nous d\u00e8s aujourd'hui pour toute question technique concernant le mod\u00e8le NU-GFPT-12-630 ou pour une solution sur mesure d'armoire de test de performance.<\/strong><\/span><\/p>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Respectueux de l'environnement : Con\u00e7u pour les armoires PT \u00e0 isolation gazeuse, respectueuses de l'environnement.<\/li>\n<li>Contr\u00f4le de pr\u00e9cision : alimentation \u00e9lectrique permettant une mesure et un contr\u00f4le fiables de la tension.<\/li>\n<li>Conception compacte : id\u00e9ale pour les installations \u00e9lectriques modernes o\u00f9 l'espace est limit\u00e9.<\/li>\n<\/ul>","protected":false},"featured_media":3243,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"NU-GFPT-12-630 PT Switch | 12kV 630A Gas-Insulated Switchgear","_seopress_titles_desc":"The NU-GFPT-12-630 PT Switch is designed for 12kV environmentally friendly gas-insulated cabinets. High stability voltage measurement and isolation for eco-friendly GIS systems.","_seopress_robots_index":""},"product_brand":[],"product_cat":[26,61],"product_tag":[269,268,266,270,267],"class_list":{"0":"post-3239","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-gas-insulated-switchgear-components","7":"product_cat-circuit-bearker","8":"product_tag-12kv-switchgear-component","9":"product_tag-gas-insulated-switchgear","10":"product_tag-nu-gfpt-12-630","11":"product_tag-potential-transformer-switch","12":"product_tag-pt-switch","14":"first","15":"instock","16":"shipping-taxable","17":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product\/3239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/comments?post=3239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/media\/3243"}],"wp:attachment":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/media?parent=3239"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3239"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3239"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}