{"id":2500,"date":"2025-11-04T02:49:19","date_gmt":"2025-11-04T02:49:19","guid":{"rendered":"https:\/\/niunielec.com\/?post_type=product&#038;p=2500"},"modified":"2026-04-16T03:34:16","modified_gmt":"2026-04-16T03:34:16","slug":"zn63vs1-40-5-36kv-indoor-ac-high-voltage-vacuum-circuit-breaker","status":"publish","type":"product","link":"https:\/\/niunielec.com\/fr\/product\/zn63vs1-40-5-36kv-indoor-ac-high-voltage-vacuum-circuit-breaker\/","title":{"rendered":"ZN63(VS1)-40.5 Disjoncteur \u00e0 vide haute tension CA d'int\u00e9rieur 36 kV"},"content":{"rendered":"<h2 id=\"h2-1\">Disjoncteur \u00e0 vide haute tension ZN63(VS1)-40,5 pour courant alternatif, \u00e0 usage int\u00e9rieur<\/h2>\n<h2 id=\"h2-2\"><strong><a href=\"https:\/\/niunielec.com\/fr\/news\/why-niuni-electric-is-your-trusted-medium-voltage-partner\/\">Disjoncteur \u00e0 vide<\/a>\u00a0<\/strong><\/h2>\n<h3><strong>Description du produit<\/strong><\/h3>\n<p>Le disjoncteur \u00e0 vide haute tension AC int\u00e9rieur ZN63(VS1)-40,5 (ci-apr\u00e8s d\u00e9nomm\u00e9 disjoncteur) est adapt\u00e9 \u00e0 l'appareillage de commutation triphas\u00e9 AC 50Hz, 40,5kV int\u00e9rieur, et peut \u00eatre utilis\u00e9 pour la protection et le contr\u00f4le des entreprises industrielles et mini\u00e8res, des centrales \u00e9lectriques et des sous-stations. Il peut \u00eatre utilis\u00e9 pour la protection et le contr\u00f4le des entreprises industrielles et mini\u00e8res, des centrales \u00e9lectriques et des sous-stations.<\/p>\n<p>Les performances de ce produit sont conformes \u00e0 la norme nationale GB1984-2003 \u00ab Disjoncteur haute tension \u00e0 courant alternatif \u00bb, JB3855 \u00ab Disjoncteur \u00e0 vide haute tension CA d'int\u00e9rieur 3,6-40,5 kV \u00bb, GB\/T11022-1999 \u00ab Exigences techniques communes pour les normes relatives aux appareillages de commutation et de commande haute tension \u00bb et IEC62271-100, ainsi que d'autres normes.<\/p>\n<h3><strong>Param\u00e8tres techniques<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"45\"><strong><b>Non.<\/b><\/strong><\/td>\n<td colspan=\"2\" width=\"424\"><strong><b>Objet<\/b><\/strong><\/td>\n<td width=\"77\"><strong><b>Unit\u00e9<\/b><\/strong><\/td>\n<td colspan=\"4\" width=\"423\"><strong><b>Donn\u00e9es<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td colspan=\"2\">Tension nominale<\/td>\n<td>KV<\/td>\n<td colspan=\"4\">40.5<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td colspan=\"2\">Courant nominal<\/td>\n<td>A<\/td>\n<td colspan=\"2\">1250<\/td>\n<td>1600<\/td>\n<td>2000 \u00a0\u00a02500<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td colspan=\"2\">Courant nominal de rupture en court-circuit<\/td>\n<td>KA<\/td>\n<td>25<\/td>\n<td>31.5<\/td>\n<td>25<\/td>\n<td>31.5<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td colspan=\"2\">Courant de stabilit\u00e9 dynamique nominal (cr\u00eate)<\/td>\n<td>KA<\/td>\n<td>63<\/td>\n<td>80<\/td>\n<td>63<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td colspan=\"2\">Courant de stabilit\u00e9 thermique 4S<\/td>\n<td>KA<\/td>\n<td>25<\/td>\n<td>31.5<\/td>\n<td>25<\/td>\n<td>31.5<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td colspan=\"2\">Courant nominal de fermeture en cas de court-circuit (cr\u00eate)<\/td>\n<td>KA<\/td>\n<td>63<\/td>\n<td>80<\/td>\n<td>63<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td colspan=\"2\">Courant de court-circuit nominal Temps de rupture<\/td>\n<td>Temps<\/td>\n<td colspan=\"4\">20<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td colspan=\"2\">S\u00e9quence de fonctionnement nominale<\/td>\n<td><\/td>\n<td colspan=\"4\">O-0,3s-CO-180s-CO<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td width=\"190\">Niveau d'isolation nominal<\/td>\n<td width=\"234\">1 min fr\u00e9quence d'alimentation tension de r\u00e9sistance<\/td>\n<td>KV<\/td>\n<td colspan=\"4\" width=\"423\">95<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td width=\"190\"><\/td>\n<td width=\"234\">Tension de tenue aux chocs de foudre (cr\u00eate)<\/td>\n<td>Temps<\/td>\n<td colspan=\"4\">185<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">Dur\u00e9e de vie m\u00e9canique<\/td>\n<td>Temps<\/td>\n<td colspan=\"4\">10000<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td colspan=\"2\" width=\"424\">Courant nominal d'ouverture et de fermeture d'une seule batterie de condensateurs<\/td>\n<td>A<\/td>\n<td colspan=\"4\">630<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td colspan=\"2\" width=\"424\">Courant nominal de la batterie de condensateurs dos \u00e0 dos<\/td>\n<td>A<\/td>\n<td colspan=\"4\">400<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td colspan=\"2\" width=\"424\">Tension nominale du moteur \u00e0 accumulation d'\u00e9nergie<\/td>\n<td>V<\/td>\n<td colspan=\"4\">AC\/DC : 110 ; 220<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td colspan=\"2\" width=\"424\">Puissance nominale du moteur \u00e0 accumulation d'\u00e9nergie<\/td>\n<td>W<\/td>\n<td colspan=\"4\">\u2264230<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td colspan=\"2\" width=\"424\">Dur\u00e9e de stockage de l'\u00e9nergie du moteur \u00e0 accumulation d'\u00e9nergie<\/td>\n<td>S<\/td>\n<td colspan=\"4\">\u226415<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td colspan=\"2\" width=\"424\">Tension nominale de la bobine d'ouverture et de fermeture<\/td>\n<td>V<\/td>\n<td colspan=\"4\">DC:110 ; 220<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td colspan=\"2\" width=\"424\">Courant nominal de la bobine d'ouverture et de fermeture<\/td>\n<td>A<\/td>\n<td colspan=\"4\">1,05(110V) 0,96(220V)<\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td colspan=\"2\" width=\"424\">Course de contact<\/td>\n<td>mm<\/td>\n<td colspan=\"4\">20\u00b12<\/td>\n<\/tr>\n<tr>\n<td>19<\/td>\n<td colspan=\"2\" width=\"424\">Course de contact de contact<\/td>\n<td>mm<\/td>\n<td colspan=\"4\">7.5\u00b11.5<\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td colspan=\"2\" width=\"424\">Ouverture triphas\u00e9e, phase de fermeture asynchrone<\/td>\n<td>ms<\/td>\n<td colspan=\"4\">\u22642<\/td>\n<\/tr>\n<tr>\n<td>21<\/td>\n<td colspan=\"2\" width=\"424\">Temps de rebond de fermeture du contact<\/td>\n<td>ms<\/td>\n<td colspan=\"4\">\u22643<\/td>\n<\/tr>\n<tr>\n<td>22<\/td>\n<td colspan=\"2\" width=\"424\">La r\u00e9sistance du circuit principal (ne comprend pas le bras de contact)<\/td>\n<td>\u03bc\u03a9<\/td>\n<td colspan=\"4\">\u226440<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong style=\"color: #555555; font-size: 20.16px;\">Dessin<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2510\" src=\"https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-768x431.webp\" alt=\"zn63(vs1) 40.5 indoor ac high voltage vacuum circuit breaker\" width=\"768\" height=\"431\" srcset=\"https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-768x431.webp 768w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-1024x575.webp 1024w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-440x247.webp 440w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-18x10.webp 18w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing-600x337.webp 600w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/11\/zn63vs1-40.5-indoor-ac-high-voltage-vacuum-circuit-breaker-drawing.webp 1319w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Ce disjoncteur \u00e0 vide est con\u00e7u pour les appareillages de commutation int\u00e9rieurs de 40,5 kV, 50 Hz. En tant que composant cl\u00e9 de protection et de contr\u00f4le, il est id\u00e9al pour les op\u00e9rations fr\u00e9quentes dans les centrales \u00e9lectriques, les sous-stations et les installations industrielles.<\/p>","protected":false},"featured_media":2506,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"ZN63(VS1)-40.5 indoor AC high-voltage vacuum circuit breaker","_seopress_titles_desc":"Explore the ZN63(VS1)-40.5 indoor AC high-voltage vacuum circuit breaker. Designed for 40.5kV, 50Hz switchgear, it provides reliable protection and control for power plants, substations, and industrial facilities.","_seopress_robots_index":""},"product_brand":[],"product_cat":[23,31],"product_tag":[100,102,96,97],"class_list":["post-2500","product","type-product","status-publish","has-post-thumbnail","product_cat-vacuum-circuit-breaker","product_cat-indoor-vacuum-circuit-breaker","product_tag-36kv-vacuum-circuit-breaker","product_tag-40-5kv","product_tag-vacuum-circuit-breaker","product_tag-vcb","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product\/2500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/comments?post=2500"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/media\/2506"}],"wp:attachment":[{"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/media?parent=2500"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2500"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2500"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/niunielec.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}