{"id":1491,"date":"2025-09-18T09:51:24","date_gmt":"2025-09-18T09:51:24","guid":{"rendered":"https:\/\/niunielec.com\/?post_type=product&#038;p=1491"},"modified":"2026-04-03T04:02:46","modified_gmt":"2026-04-03T04:02:46","slug":"10kv-12kv-withdrawable-vacuum-circuit-breaker-3-pole-vcb-for-electrical-panel","status":"publish","type":"product","link":"https:\/\/niunielec.com\/es\/product\/10kv-12kv-withdrawable-vacuum-circuit-breaker-3-pole-vcb-for-electrical-panel\/","title":{"rendered":"Interruptor de vac\u00edo extra\u00edble de 10 kV y 12 kV, de 3 polos, para cuadro el\u00e9ctrico"},"content":{"rendered":"<h2 id=\"h2-1\"><strong><span style=\"font-size: 75%;\">Interruptor de vac\u00edo extra\u00edble de 10 kV y 12 kV, de 3 polos, para cuadro el\u00e9ctrico<\/span><\/strong><\/h2>\n<h3><strong><span style=\"font-size: 75%;\">Descripci\u00f3n del producto<\/span><\/strong><\/h3>\n<p>(ZN63)VS1-12 indoor high voltage handcart vacuum circuit breaker is applied to 7.2KV~12KV, three-phase, AC50Hz\/60Hz. It is applicable in occasions with frequent operations, acting to protect and control line and electric apparatus. The product conforms to IEC62271-100, GB1984. It can be used in KYN28A-12 and other center-mounted handcart switchgears. The fixed type could also be used in the XGN series fixed switchgear.<\/p>\n<h3><span style=\"font-size: 75%;\"><strong>Par\u00e1metros t\u00e9cnicos<\/strong><\/span><\/h3>\n<table style=\"border-collapse: collapse; width: 54.5819%; height: 931px;\">\n<tbody>\n<tr style=\"height: 21px;\">\n<td style=\"width: 100%; height: 21px;\" colspan=\"5\"><strong><b>Principales par\u00e1metros t\u00e9cnicos<\/b><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Nombre del art\u00edculo<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Unidad<\/span><\/td>\n<td style=\"width: 60%; height: 21px;\" colspan=\"3\"><span style=\"font-size: 90%;\">Datos<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tensi\u00f3n nominal<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">kv<\/span><\/td>\n<td style=\"width: 60%; height: 21px;\" colspan=\"3\"><span style=\"font-size: 90%;\">12<\/span><\/td>\n<\/tr>\n<tr style=\"height: 64px;\">\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">Frecuencia nominal de trabajo a corto plazo Tensi\u00f3n soportada(1 Min)<\/span><\/td>\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">kv<\/span><\/td>\n<td style=\"width: 60%; height: 64px;\" colspan=\"3\"><span style=\"font-size: 90%;\">42<\/span><\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">Tensi\u00f3n nominal soportada por impacto de rayo (pico)<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">kv<\/span><\/td>\n<td style=\"width: 60%; height: 43px;\" colspan=\"3\"><span style=\"font-size: 90%;\">75<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Frecuencia nominal<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Hz<\/span><\/td>\n<td style=\"width: 60%; height: 21px;\" colspan=\"3\"><span style=\"font-size: 90%;\">50<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Corriente nominal<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">A<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">630 1250<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">1600.2000.2500. 3150.4000<\/span><\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">Corriente nominal de corte en cortocircuito<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">KA<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">25<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">31.5<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">40<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Corriente nominal de corta duraci\u00f3n<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">KA<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">25<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">31.5<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">40<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Duraci\u00f3n nominal del cortocircuito<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">S<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">4<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">4<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Corriente nominal de pico soportada<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">KA<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">63<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">80<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">100<\/span><\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">Corriente nominal de cierre en cortocircuito<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">KA<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">63<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">80<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">100<\/span><\/td>\n<\/tr>\n<tr style=\"height: 64px;\">\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">Frecuencia de alimentaci\u00f3n del circuito secundario Tensi\u00f3n soportada(1Min)<\/span><\/td>\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">V<\/span><\/td>\n<td style=\"width: 60%; height: 64px;\" colspan=\"3\"><span style=\"font-size: 90%;\">2000<\/span><\/td>\n<\/tr>\n<tr style=\"height: 64px;\">\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">Corriente nominal de conexi\u00f3n y desconexi\u00f3n de bater\u00edas de condensadores simples\/contrapuestas<\/span><\/td>\n<td style=\"width: 20%; height: 64px;\"><span style=\"font-size: 90%;\">A<\/span><\/td>\n<td style=\"width: 60%; height: 64px;\" colspan=\"3\"><span style=\"font-size: 90%;\">630\/400 (40KA es 800\/400)<\/span><\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">Corriente nominal de cierre del banco de condensadores<\/span><\/td>\n<td style=\"width: 20%; height: 43px;\"><span style=\"font-size: 90%;\">KA<\/span><\/td>\n<td style=\"width: 60%; height: 43px;\" colspan=\"3\"><span style=\"font-size: 90%;\">12,5 (frecuencia\u22641000Hz)<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tiempo de frenado<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">ms<\/span><\/td>\n<td style=\"width: 60%; height: 21px;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u226450<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Hora de cierre<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">ms<\/span><\/td>\n<td style=\"width: 60%; height: 21px;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u226470<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Vida mec\u00e1nica<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Times<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">30000<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Se permite el espesor de desgaste de los contactos din\u00e1micos y est\u00e1ticos<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\" width=\"40\"><span style=\"font-size: 90%;\">mm<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">3<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tensi\u00f3n nominal de cierre<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">V<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">AC110\/220 DC110\/220<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tensi\u00f3n nominal de funcionamiento de disparo<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">V<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">AC110\/220 DC110\/220<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tensi\u00f3n nominal del motor de almacenamiento de energ\u00eda<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">V<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">AC110\/220 DC110\/220<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Potencia nominal del motor de almacenamiento de energ\u00eda<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">W<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">90<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Tiempo de almacenamiento de energ\u00eda<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">S<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u226415<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Contacto<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">mm<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">9\u00b11<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Sobre Viajes<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">mm<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">3.5\u00b10.5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Contacto Cierre Tiempo de rebote<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\" width=\"40\"><span style=\"font-size: 90%;\">ms<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u22642<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">La separaci\u00f3n trif\u00e1sica y el cierre no son del mismo periodo<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">ms<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u22642<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Velocidad media de rotura (separaci\u00f3n de contactos-5Mm)<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">m\/s<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">0.9-1.3<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Velocidad media de cierre (cierre por contacto de 5 mm)<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">m\/s<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">0.6-1.0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Freno de mano<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">mm<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u22642<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Resistencia del circuito principal<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">\u03bc\u03a9<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">\u226450(630), \u226445(1000\/1250), \u226435(1600\/2000), \u226425(2500\/3150), \u226420(4000)<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Presi\u00f3n de cierre de los contactos<\/span><\/td>\n<td style=\"width: 20%;\" width=\"40\"><span style=\"font-size: 90%;\">N<\/span><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">3100\u00b1200(25-31,5KA) \/ 4600\u00b12500(40KA)<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 20%; height: 21px;\"><span style=\"font-size: 90%;\">Secuencia de operaciones<\/span><\/td>\n<td style=\"width: 20%; height: 21px;\"><\/td>\n<td style=\"height: 21px; width: 60%;\" colspan=\"3\"><span style=\"font-size: 90%;\">O-0,3s-CO-180S-CO<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span style=\"font-size: 75%;\"><strong>Interruptor de vac\u00edo extra\u00edble de 10 kV y 12 kV, de 3 polos, para cuadro el\u00e9ctrico<\/strong><\/span><\/h3>\n<h4><strong>Dibujo<\/strong><\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1680\" src=\"https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing.webp\" alt=\"10kv 12kv disyuntor de vacio 3 polos tipo fijo vcb para cuadro electrico de media tension\" width=\"955\" height=\"671\" srcset=\"https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing.webp 1302w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing-440x309.webp 440w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing-768x540.webp 768w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing-1024x720.webp 1024w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing-18x12.webp 18w, https:\/\/niunielec.com\/wp-content\/uploads\/2025\/09\/drawing-600x422.webp 600w\" sizes=\"auto, (max-width: 955px) 100vw, 955px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>(ZN63)VS1-12 indoor high voltage handcart vacuum circuit breaker is applied to 7.2KV~12KV, three-phase, AC50Hz\/60Hz. It is applicable in occasions with frequent operations, acting to protect and control line and electric apparatus.<\/p>\n<p>El producto cumple las normas IEC62271-100, GB1984. Puede utilizarse en KYN28A-12 y otras celdas manuales de montaje central.<\/p>\n<p>El tipo fijo tambi\u00e9n puede utilizarse en la aparamenta fija de la serie XGN.<\/p>","protected":false},"featured_media":1678,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"23","_seopress_titles_title":"10KV 12KV Withdrawable Vacuum Circuit Breaker 3 Pole VCB for Electrical Panel","_seopress_titles_desc":"(ZN63)VS1-12 indoor high voltage withdrawable vacuum circuit breaker is applied to 7.2KV~12KV, three-phase, AC50Hz\/60Hz. It is applicable in occasions with frequent operations, acting to protect and control line and electric apparatus.","_seopress_robots_index":""},"product_brand":[],"product_cat":[23,31],"product_tag":[98,99,96,97],"class_list":{"0":"post-1491","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-vacuum-circuit-breaker","7":"product_cat-indoor-vacuum-circuit-breaker","8":"product_tag-12kv-vacuum-circuit-breaker","9":"product_tag-24kv","10":"product_tag-vacuum-circuit-breaker","11":"product_tag-vcb","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/product\/1491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/comments?post=1491"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/media\/1678"}],"wp:attachment":[{"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/media?parent=1491"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/product_brand?post=1491"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/product_cat?post=1491"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/niunielec.com\/es\/wp-json\/wp\/v2\/product_tag?post=1491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}